A sauna control sets the temperature and on-time of an electric sauna heater. Some heaters have their controls built in; others run from a separate control, and the heater's manufacturer says which controls may be used with it. This guide lists only pairings a manufacturer publishes for the exact heater model we carry, taken from our compatibility records, which are built from manufacturer manuals and product pages.

6 of the 19 products in our sauna heater controls range have a heater pairing published by their manufacturer for an exact heater we carry. For the others, we hold no manufacturer document that names that exact control for a specific heater we carry, so they are not paired here.

We carry 100 sauna heaters. 31 are wood-burning stoves, which take no electric control, so this guide covers the other 69. Of those, 16 have a control we sell named by the manufacturer for that exact model, 5 have built-in controls, 18 have a manufacturer statement about the kind of control they take without naming a model, and 30 are not covered here yet.

Built in or separate?

Controls the manufacturer pairs with each heater

Each row is a pairing the heater's manufacturer publishes for that exact model. Where the manual pairs them only at a particular supply or connection, that condition is shown; your electrician confirms the supply and connection from the heater's installation manual. A pairing for one output or supply version does not carry over to another.

HUUM

Heater Control Condition in the manual
HUUM HIVE 12 HUUM UKU Extension Box the extension box manual lists this heater in its connection scheme
HUUM HIVE 15 HUUM UKU Extension Box the extension box manual lists this heater in its connection scheme
HUUM HIVE 18 HUUM UKU Extension Box the extension box manual lists this heater in its connection scheme

Harvia

Heater Control Condition in the manual
Harvia Cilindro PC60E Harvia Fenix FX30-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)
Harvia Cilindro PC60E Harvia Fenix FX45-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)
Harvia Cilindro PC60E Harvia Xenio CX30-U1-U3-XW 240 V, 1-phase (1-group or 2-group connection)
Harvia Cilindro PC60E Harvia Xenio CX45-U1-U3-XW 240 V, 1-phase (1-group or 2-group connection)
Harvia Cilindro PC80E Harvia Fenix FX30-U1-U3-XC 240 V, 1-phase (2-group connection)
Harvia Cilindro PC80E Harvia Fenix FX45-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)
Harvia Cilindro PC80E Harvia Xenio CX30-U1-U3-XW 240 V, 1-phase (2-group connection)
Harvia Cilindro PC80E Harvia Xenio CX45-U1-U3-XW 240 V, 1-phase (1-group or 2-group connection)
Harvia Cilindro PC90E Harvia Fenix FX30-U1-U3-XC 240 V, 1-phase (2-group connection)
Harvia Cilindro PC90E Harvia Fenix FX45-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)
Harvia Cilindro PC90E Harvia Xenio CX30-U1-U3-XW 240 V, 1-phase (2-group connection)
Harvia Cilindro PC90E Harvia Xenio CX45-U1-U3-XW 240 V, 1-phase (1-group or 2-group connection)
Harvia Cilindro PC110E Harvia Fenix FX30-U1-U3-XC 240 V, 1-phase (2-group connection)
Harvia Cilindro PC110E Harvia Fenix FX45-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)
Harvia Cilindro PC110E Harvia Xenio CX30-U1-U3-XW 240 V, 1-phase (2-group connection)
Harvia Cilindro PC110E Harvia Xenio CX45-U1-U3-XW 240 V, 1-phase (1-group or 2-group connection)
Harvia Spirit SP60E Harvia Xenio CX30-U1-U3-XW 240 V, 1-phase
Harvia Spirit SP60E Harvia Xenio CX45-U1-U3-XW 240 V, 1-phase
Harvia Spirit SP80E Harvia Xenio CX30-U1-U3-XW 240 V, 1-phase (2-group connection)
Harvia Spirit SP80E Harvia Xenio CX45-U1-U3-XW 240 V, 1-phase
Harvia Virta 6 Harvia Fenix FX30-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)
Harvia Virta 6 Harvia Fenix FX45-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)
Harvia Virta 8 Harvia Fenix FX30-U1-U3-XC 240 V, 1-phase (2-group connection)
Harvia Virta 8 Harvia Fenix FX45-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)
Harvia Virta 9 Harvia Fenix FX30-U1-U3-XC 240 V, 1-phase (2-group connection)
Harvia Virta 9 Harvia Fenix FX45-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)
Harvia Virta 11 (208V, 3PH) Harvia Fenix FX30-U1-U3-XC 208 V, 3-phase (1-group connection)
Harvia Virta 11 (208V, 3PH) Harvia Fenix FX45-U1-U3-XC 208 V, 3-phase (1-group connection)
Harvia Virta 11 (240V, 1PH) Harvia Fenix FX30-U1-U3-XC 240 V, 1-phase (2-group connection)
Harvia Virta 11 (240V, 1PH) Harvia Fenix FX45-U1-U3-XC 240 V, 1-phase (1-group or 2-group connection)

Saunum

Heater Control Condition in the manual
Saunum Air 5 Saunum AirIQ the only control the manual allows
Saunum Air 7 Saunum AirIQ the only control the manual allows
Saunum Air L 10 Saunum AirIQ the only control the manual allows
Saunum Air L 13 Saunum AirIQ the only control the manual allows
Saunum Air L 15 Saunum AirIQ the only control the manual allows

If your heater is not listed

How to check your exact model

  1. Note your heater's exact model, output and supply version.
  2. Open its installation manual on our manuals page and find the control units listed for that exact model.
  3. Check the room against the heater's published range in the sauna heater sizing guide.
  4. Circuit, breaker and wire sizes come from that manual. Have a licensed electrician confirm them before installation.

Still deciding which setup is right for you? Request a private quote or ask us a question.